2000A High Current Low Noise Level Series Output Reactor for Inverter/Governor with Temperature Control System

Product Details
Customization: Available
Application: Power, Electronic, Instrument, Lighting, Rectifier, Audio
Phase: Three
Gold Member Since 2018

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

In-stock Capacity
The supplier has In-stock capacity
Fast Delivery
The supplier can deliver the goods within 15 days
Low MOQ
The MOQ for the supplier's products is 1
Management Certification
The supplier has quality management system certification, including:
ISO9001:2015 certificate
to see all verified strength labels (24)
  • 2000A High Current Low Noise Level Series Output Reactor for Inverter/Governor with Temperature Control System
  • 2000A High Current Low Noise Level Series Output Reactor for Inverter/Governor with Temperature Control System
  • 2000A High Current Low Noise Level Series Output Reactor for Inverter/Governor with Temperature Control System
  • 2000A High Current Low Noise Level Series Output Reactor for Inverter/Governor with Temperature Control System
  • 2000A High Current Low Noise Level Series Output Reactor for Inverter/Governor with Temperature Control System
Find Similar Products
  • Overview
  • Certifications
  • FAQ
Overview

Basic Info.

Model NO.
RE-14
Core
Core-type Transformer
Cooling Method
Dry-type Transformer
Winding Type
Auto-transformer
Certification
ISO9001-2000, CE
Usage
Single-phase Transformer, Rectifier Transformer, Combined Transformer, Power Transformer, Distribution Transformer
Frequency Characteristics
High Frequency
Brand
Xin Poming/Po Ming
Insulation Resistance
1000VDC
Noise
<50dB
Rated Working Voltage
380V/50Hz or 660V/50Hz
Protection
IP00
Insulation Grade
Above F
Rated Current
1-1500(a)
Transport Package
Wooden Case
Trademark
Xin Poming/Po Ming
Origin
Shenzhen, Guangdong, China
HS Code
8504409900
Production Capacity
8000 Piece Per Month

Product Description


Product Description
An reactor is also called an inductor. When a conductor is energized, it will generate a magnetic field within a certain space occupied by it.However, the inductance of the long direct conductor is small and the magnetic field is not strong.Sometimes, in order to give the solenoid a greater inductance, an iron core is inserted into the solenoid, called an iron core reactor.
 

Purposes of reactor:

1.Current limiting reactor.It is with power circuit in series to restrict value of short-circuit current.

2.Paralleling reactor.It is generally connected between end side of ultrahigh voltage transmission wire and ground and has the action of reactive power compensation.

3.Communication reactor.It is also known as wave absorber.It is connected in series in the power transmission line for communication line to resist carrier signal and make it into receiving equipment.

4.Arc suppression reactor.It is also called as arc suppression coil.Connected between neutral point of 3-phase transformer and ground for supplying inductive current when one phase of 3 phase power grid is grounded,to compensate capacitive current going through the grounding point,cause uneasy ignition due to arc and remove overvoltage due to multiple ignitions of arc.

5. Harmonic Filter Reactor.It is used for ripple wave amplitude of bamboo current in rectification circuit;it can move the voltage or current of a harmonic wave of power circuit which formed a circuit with capacitors to generate resonance at a frequency.

6.Electric furnace reactor.It is connected in series with electric furnace transformer to restrict its short-circuit current.

7.Starting reactor.It is connected in series with motor to restrict its starting current.

 Technical parameters:

  1.Insulation resistance:1000VDC Insulation resistance≥100MV;

    2.Dielectric strength:iron core-winding 3000VAC/50Hz/5mA/10s non arc breakdown (testing at factory)

    3.Input reactor noise:less than 65dB(testing at the horizontal distance of 1m to the reactor)

    4.Rated working voltage:380V/50Hz or 660V/50Hz

    5.Protection level:IP00

    6.Insulation grade:above F

    7.Insulation structure:dry type reactor

    8.With/without iron core:iron core reactor/air core reactor

    9.Product certification:CE

    10.Rated current:3-2000(A)

    11.Rated voltage of system:0.69/1.14(kV)

    12.Applicable standard:

      (1)1987 reactor

      (2)GB10229-88 reactor(eqv IEC289:1987)

      (3)JB9644-1999 reactor for electric drive of semi-conductor

Action of reactor:

The current limitation and wave filtration of reactor can restrict the short-circuit current of transmission line and protect electric equipment.Reactors must be installed.Reactors can reduce short-circuit and keep the voltage of system unchanged at the moment of short circuit.A damping reactor(i.e. series reactor)is stalled in the circuit of reactor,which has the action of depressing surge when active.It forms harmonic circuit with capacitors and takes the action of harmonic filtration.

Capacity of frequency converter(KW)

 

Input reactor Model N.o.

 Dimension: L(A)xW(B)xH(H) (mm)

 

 Install dimension

 E×F

(mm)

 

Output reactor Model N.o.

 

 Dimension: L(A)×W(B)×H(H)

 (mm)

 Install dimension E×F

(mm)

 0.75

0200075

140×80×140

80×50

0100075

140×80×140

80×50

 1.5

0200150

140×80×140

80×50

0100150

140×80×140

80×50

 2.5

0200250

140×80×140

80×50

0100250

140×80×140

80×50  

  4

0200400

140×80×140

80×50

0100400

140×80×140

80×50

 5.5

0200550

150×90×140

120×55

0100550

140×90×140

120×55

 7.5

0200750

150×110×130

120×55

0100750

150×110×130

120×55

 11

201100

150×120×130

120×60

0101100

150×120×130

120×60

 15

0201500

150×120×130

140×70

0101500

150×120×130

140×70

 18

0201800

175×150×130

140×70

0101800

175×150×130

140×70

 22

0202200

175×150×130

140×70

0102200

175×150×130

140×70

 30

0203000

200×150×160

170×80

0103000

200×150×160

170×80

 37

0203700

200×150×160

170×80

0103700

200×150×160

170×80

 45

0204500

240×140×190

200×80

0104500

240×140×190

200×80

 55

0205500

240×150×190

200×90

0105500

240×150×190

200×90

 75

0207500

240×160×190

200×100

0107500

240×160×190

200×100

 90

0209000

260×190×270

220×110

0109000

260×190×270

220×110

 110

02110000

260×190×270

220×110

01110000

260×190×270

220×110

 132

02132000

270×190×280

220×120

01132000

270×190×280

220×120

 160

02160000

300×195×290

250×120

01160000

300×195×290

250×120

 187

02187000

320×195×290

250×120

01187000

320×195×290

250×120

 200

02200000

320×195×290

250×120

01200000

320×195×290

250×120

 220

02220000

320×210×300

250×130

01220000

320×210×300

250×130

 250

2250000

320×210×300

250×130

01250000

320×210×300

250×130

 315

02315000

340×240×300

270×140

YLLK01315000

340×240×300

270×140

 375

02375000

380×250×360

300×150

YLLK01375000

380×250×360

300×150

 400

02400000

380×250×360

300×150

YLLK01400000

380×250×360

300×150

2000A High Current Low Noise Level Series Output Reactor for Inverter/Governor with Temperature Control System

Action of reactor:

The current limitation and wave filtration of reactor can restrict the short-circuit current of transmission line and protect electric equipment.Reactors must be installed.Reactors can reduce short-circuit and keep the voltage of system unchanged at the moment of short circuit.A damping reactor(i.e. series reactor)is stalled in the circuit of reactor,which has the action of depressing surge when active.It forms harmonic circuit with capacitors and takes the action of harmonic filtration.

 

Shenzhen Xin Poming Power Equipment Manufacturing Co., Ltd is established in Guangdong Province of China in 2007, which manufactures and sells voltage regulators, transformers, UPSs, frequency converter, DC power sources and other power products and can provide systemic power solutions for customers with it's complete product list For clients around the world .

2000A High Current Low Noise Level Series Output Reactor for Inverter/Governor with Temperature Control System
2000A High Current Low Noise Level Series Output Reactor for Inverter/Governor with Temperature Control System
Certifications

 

2000A High Current Low Noise Level Series Output Reactor for Inverter/Governor with Temperature Control System
FAQ

Q1: What is the MOQ ?

A1: 1 set.

Q2: Is OEM/ODM available?
A2: Yes, it is! Our products can be Customized. We have design and engineer teams,we can customize products according to customers' drawing or requirements.

Q3: Can we put/show our own Logo on your products?
A3: Yes.

Q4: What is the Terms of Payment?
A4: T/T, Western Union.

Q5: Can you offer Form A or Form E or C/O ? 
A5: Yes, no problem, we can apply for it from our local government.

Q6: How is the delivery time ? 
A6: It depends your order quantity and it normally takes 3-20 days .

Q7: How long is the service life ?
A7: It is 20-30 years. 

Q8: How long is the warranty ?
A8: Within one year from the sale date, if there are any accessory problems,
you just provide the photos of damaged accessory, then we will provide free accessory.
According to the number of products, we will provide easily damaged accessories for free.
We also can provide technical support if you need.


You're welcomed to contact us for any questions.
2000A High Current Low Noise Level Series Output Reactor for Inverter/Governor with Temperature Control System

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now